Specification | |
IR Temp. range | -40~500°C |
Temp. resolution | 0.1°C/°F(-40~110°C), others 1°C/°F |
Temp. accuracy (Which is greater) |
+/-2%or 2°C at -20 ~200°C,others is +/-3%or 3°C |
Repeatability | +/-1°C |
Emissivity | 0.3~1.0 adjustable |
D:S ratio | 10:1 |
External temp. range | -20~150°C |
Ext. temp. accuracy | +1.2°C ( -20~0°C /- 4 ~32°F) +0.8°C (0~50°C/32~122°F) +1.6°C(50~100°C/122~212°F) +3.0°C(100~150°C/212 ~302°F) |
LCD size | 26(H)x45(W)mm |
Operating temp. | 0~50°C |
Operating RH% | Humidity < 80% |
Storage temp. | -20~50°C |
Storage RH% | Humidity < 90% |
Dimension | 170x70x40(H) mm |
Weight | 210g |
Battery | AAA battery x 4pcs |
Standard Package | Meter/Battery/Manual/software/ cable/hard carry case/External temp. Probe (VZ981PAZ), 9612 only |
- ADDING PROBE TO MEASURE WIDED RANGE AND PENETRATE OBJECT'S INTERNAL TEMP.
- EASY TO SET UP : TIME, SAMPLE INTERVAL, HI/LO ALARM SAMPLE INTERVAL FROM 1 SEC TO 2 HOURS.
- VIEWING RECORDING STATUS BY PRESSING BUTTON.
- DOWN LOADING DATA OR UP LOADING 99 MEASUREMENT
- LOCATION (FILE NAMES ) VIA PC PRE-EDITING.
Comments are closed.