Multifunction Process Calibrator
Precision Current & Voltage & Thermocouple Source/Measure Calibrator
The PRC30 is a Multifunction Process Calibrator. This calibrator provides precision sourcing and measurements for thermocouples (eight types), current (mA), and voltage (mV and V) devices. Featuring 24 volt loop power, five user adjustable calibration presets, and temperature output in Fahrenheit, Celsius, and millivolts. Product includes test leads, alligator clips, thermocouple calibration cable, universal calibration cable, 100-240V AC universal adapter with 4 plugs, AA batteries, hard case, and user manual.
Specifications | Range | Basic Accuracy |
DC Source | ||
---|---|---|
Current | 0 to 24mA, -25% to +125% | ±(0.01% + 1 digit) |
Max. Load | 1000Ω @ 24mA | |
Voltage | 0 to 2000mV, 0 to 20V | ±(0.01% + 1 digit) |
mV/Temp | -5 to 55mV | ±(0.01% + 1 digit) |
Type J | -58 to 1832°F (-50 to 1000°C) | ±(0.05% + 2°F or 1°C) |
Type K | -58 to 2498°F (-50 to 1370°C) | ±(0.05% + 2°F or 1°C) |
Type T | -184 to 752°F (-120 to 400°C) | ±(0.05% + 2°F or 1°C) |
Type E | -58 to 1382°F (-50 to 750°C) | ±(0.05% + 2°F or 1°C) |
Type C, R, S | 32 to 3182°F (0 to 1750°C) | ±(0.05% + 2°F or 1°C) |
Type N | -58 to 2372°F (-50 to 1300°C) | ±(0.05% + 2°F or 1°C) |
DC Measure | ||
Current | 0 to 50mA, -25% to +230% | ±(0.01% + 1 digit) |
Voltage | 0 to 1999mV / 2 to 20V | ±(0.01% + 1 digit) / auto range |
mV/Temp | -10 to 60mV | ±(0.01% + 1 digit) |
Type J | -58 to 1832°F (-50 to 1000°C) | ±(0.05% + 1.8°F or 1°C) |
Type K | -58 to 2498°F (-50 to 1370°C) | ±(0.05% + 1.8°F or 1°C) |
Type T | -184 to 752°F (-120 to 400°C) | ±(0.05% + 1.8°F or 1°C) |
Type E | -58 to 1382°F (-50 to 750°C) | ±(0.05% + 1.8°F or 1°C) |
Type C, R, S | 32 to 3182°F (0 to 1750°C) | ±(0.05% + 2°F or 1°C) |
Type N | -58 to 2372°F (-50 to 1300°C) | ±(0.05% + 2°F or 1°C) |
Loop Power | 24V | |
Dimensions | 6.3" x 3.2" x 1.7" (159 x 80 x 44mm) | |
Weight | 8.4oz (236g) |
- 0 to 24mA (-25 to 125%) readout
- 24V DC power source for 2-wire current loop
- 0 to 20V DC calibration source
- Source and measure 8 thermocouple type devices (J, K, T, E, C, R, S and N)
- CJC - Cold Junction Compensation function
- Up to five user adjustable calibration presets
- Palm-sized double molded housing and large dot-matrix backlit LCD
- High accuracy calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, controllers or recorders
- Displays output in terms of millivolts or temperature based on thermocouple tables
- Zero adjustment, auto zero when power on and change mode
- Standard banana I/O ports and mini thermocouple connector
- Large battery bank for extended work cycle
- External power adapter for continuous work cycle
- Complete with test leads, alligator clips, calibration cables, 100V-240V AC universal adaptor with 4 plugs, six AA batteries, and hard carrying case
Comments are closed.