The Fluke 373 Clamp Meter offers improved performance perfect for any AC only current measurement situations. Featuring True RMS AC voltage and current measurements, and resistance measurement up to 6000 Ω with continuity detection, the Fluke 373 is everything you need, plus a little more.
Electrical Specifications | |
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (48 – 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 @ 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0 % ± 5 digits (48 – 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1 % ± 5 digits |
Resistance | |
Range | 600.0 Ω/6000 Ω |
Resolution | 0.1 Ω/1 Ω |
Accuracy | 1 % ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 – 100.0 μF / 1000 μF |
Resolution | 0.1 μF/1 μF |
Accuracy | 1.9 % ± 2 digits |
Mechanical Specifications | |
Size (L x W x H) | 232 mm x 85 mm x 45 mm |
Weight | 370 g |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temp | -40 °C to +60 °C |
Operating Humidity | Non condensing (< 10 °C) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) (Without Condensation) |
Operating Altitude | 3000 meters |
Storage Altitude | 12,000 meters |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
Batteries | 2 AA, NEDA 15A, IEC LR6 |
Features and benefits
- 600 A ac current measurement with fixed jaw
- 600 VAC and DC voltage measurement
- State of the art signal processing allows for use in noisy electrical environments while providing stable readings
- CAT IV 300 V, CAT III 600 V
- True RMS AC voltage and current for accurate measurements on non-linear signals
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
- Soft carrying case
Comments are closed.