The fast one-handed tool for mA loop checks in Ex zones
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.
Specifications | ||
Current measurement | Range | 0 to 24 mA |
Resolution | 0.001 mA | |
Accuracy | 0.015% Rdg + 2 LSD | |
Current sourcing | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.015% Rdg + 2 LSD | |
Drive capability | 700 Ω at 20 mA | |
Current simulation | Range | 0 to 20 mA or 4 to 20 mA |
Accuracy | 0.015% Rdg + 2 LSD | |
Loop power | While measuring mA, 24 V | |
Voltage measurement | Range | 0 to 28 V DC |
Resolution | 1 mV | |
Accuracy | 0.015% Rdg + 2 LSD | |
Environmental Specifications | ||
Operating temperature | -10ºC to 55ºC | |
Storage temperature | -40ºC to 60ºC | |
Humidity (without condensation) | 0 to 95% (0ºC to 30ºC); | |
0 to 75% (30ºC to 40ºC) |
||
0 to 45% (40ºC to 50ºC) |
||
Temperature coefficient | -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC | |
Safety Specifications | ||
Safety | CSA C22.2 No. 1010.1:1992 | |
EMC | EN50082-1:1992 and EN55022:1994 Class B | |
Maximum voltage | 30 V | |
ATEX certification | Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X | |
CE certification | EN61010-1 and EN61326 | |
Mechanical and General Specifications | ||
Size | 152 x 70 x 41 mm | |
Weight | 224 g (350 g including holster) | |
Batteries | One 9V battery Alkaline | |
Shock & vibration | per MIL-T-28800 for a Class 2 Instrument | |
Display current and % of span | Yes | |
Auto step, auto ramp | Yes | |
Span check | Yes |
- Large display and simple, quick-click push rotary button for easy one-handed operation
- Simultaneous mA and % readout for quick, easy, interpretation of readings.
- mA accuracy of 0.015%, superior to other loop calibrators
- 1 µA resolution for mA source, simulate and measure
- Push button with 25% steps for fast, easy linearity checks
- 0-100% "span check" for fast confirmation of zero and span
- Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
- Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
- Measures Vdc to 28 V
- Single 9 V battery that is easily changed
- 0-20 mA or 4-20 mA default start up modes
- Innovative output adjustment dial with 1 µA and 100 µA resolution
- HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators