Small dry wells for big field applications
The 9144 Series Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25°C to 660°C.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport. Optimized for speed, Field Metrology Wells cool to –25°C in 15 minutes and heat to 660°C in 15 minutes.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13°C to 33°C.
Base Unit Specifications | |
Temperature range at 23°C | 50°C to 660°C (122°F to 1220°F) |
Display accuracy | ±0.35°C at 50°C ±0.35°C at 420°C ±0.5°C at 660°C |
Stability | ±0.03°C at 50°C ±0.04°C at 420°C ±0.05°C at 660°C |
Axial uniformity at 40 mm (1.6 in) | ±0.05°C at 50°C ±0.35°C at 420°C ±0.5°C at 660°C |
Radial uniformity | ±0.02°C at 50°C ±0.05°C at 420°C ±0.10°C at 660°C |
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ±0.015°C at 50°C ±0.025°C at 420°C ±0.035°C at 660°C |
Hysteresis | 0.1 |
Operating conditions | 0°C to 50°C, 0% to 90% RH (non-condensing) |
Environmental conditions (for all specifications except temperature range) | 13°C to 33°C |
Immersion (well) depth | 150 mm (5.9 in) |
Insert OD | 24.4 mm (0.96 in) |
Heating time | 15 min: 50°C to 660°C |
Cooling time | 25 min: 660°C to 100°C 35 min: 660°C to 50°C |
Resolution | 0.01° |
Display | LCD, °C or °F user-selectable |
Size (H x W x D) | 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in) |
Weight | 7.7 kg (17 lb) |
Power requirements | 100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W |
Computer interface | RS-232 and 9930 Interface-it control software included |
-P Specifications | |
Built-in reference thermometer readout accuracy (4-wire reference probe)1 | ±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C |
Reference resistance range | 0 ohms to 400 ohms |
Reference resistance accuracy2 | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading |
Reference characterizations | ITS-90, CVD, IEC-751, Resistance |
Reference measurement capability | 4-wire |
Reference probe connection | 6-pin Din with Infocon Technology |
Built-in RTD thermometer readout accuracy | NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C |
RTD resistance range | 0 ohms to 400 ohms |
RTD resistance accuracy2 | 25 ohms to 400 ohms: ±80 ppm of reading 0 ohms to 25 ohms: ±0.002 ohms |
RTD characterizations | PT-100 (385),(JIS),(3926), NI-120, Resistance |
RTD measurement capability | 4-wire RTD (2-,3-wire RTD w/ Jumpers only) |
RTD connection | 4 terminal input |
Built-in TC thermometer readout accuracy | Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C |
TC millivolt range | –10 mV to 75 mV |
Voltage accuracy | 0.025% of reading + 0.01 mV |
Internal cold junction compensation accuracy | ±0.35°C (ambient of 13°C to 33°C) |
TC connection | Small connectors |
Built-in mA readout accuracy | 0.02% of reading + 2 mV |
mA range | Cal 4-22 mA, Spec 4-24 mA |
mA connection | 2 terminal input |
Loop power function | 24 V DC loop power |
Built-in electronics temperature Coefficient (0°C to 13°C, 33°C to 50°C) | ±0.005% of range per°C |
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. |
- Lightweight, portable, and fast
- Cool to –25°C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01°C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading