3 Phase Power Analyser Lutron DW-6095 brings basic power analysis, and fault finding within the grasp of most technicians. Included is a complete, ready to use kit for measuring all power parameters on industrial installations to 1200A, with extension using clamp CP3000 to 3000A.
Specifications | ||
Circuit | Custom one-chip of microprocessor LSI circuit | |
Display | LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch ) Dot Matrix LCD (320 X 240 pixels ) with back light. |
|
Measurement | V (phase-to-phase) V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Power factor Phase angle Frequency Harmonics display |
|
Wire connections | 1P/2W, 1P/3W, 3P/3W, 3P/4W. | |
Voltage ranges | 10 ACV to 600 ACV, auto range | |
Current probe input signal and range | Current probe input signal volage ( ACV ) : 200mV/300mV/500mV/1V/2V/3V Current probe input current range ( ACA ) : 20 A/200A/2000A (1200 A)/30A/300A/3000A Meter can cooperate the universal current probe |
|
Safety standard | IEC1010 CAT III 600 V | |
ACV input impedance | 10 Mega ohms. | |
Range select | ACV | Auto range |
ACA | Manual range | |
Clamp frequency response | 40 Hz to 1 KHz | |
Spec. tested frequency | 45 to 65 Hz | |
Over load protection | ACV | 720 ACV rms |
ACA | 1300 ACA with clamp probe * For the Clamp ,CP-1201 |
|
Data Hold | Freeze the display reading | |
Data Record | SD Card Record | |
Sampling Time | Approx. 1 second | |
Power ON/OFF | Manual OFF by push button | |
Over Indicator | LCD display show " OL " The data save into the SD card will show " 9999 " or " 999 " ( overleap the decimal point ) |
- Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W.
- 3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary
- Current probe input signal/ranges with selection :
Input signal (ACV) :
200 mV/300 mV/500 mV/1 V/2 V/3 V
Ranges (ACA) :
20 A/200 A/2000 A/30 A/300 A/ 3000 A. - Meter can cooperate the universal current probes.
- * Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe ( CP 1201 ), AC to DC 9V adapter, 2G SD memory card and Carrying bag
- Measurement :
V (phase-to-phase), V (phase-to-ground)
A (phase-to-ground)
KW / KVA / KVAR / PF (phase)
KW / KVA / KVAR / PF (system)
KWH / KVAH / KVARH / PFH (system)
Phase angle - Harmonics display (1-50th order).
- Simultaneous display of Harmonics and Wave form.
- Display of Waveform with Peak Values.
- Analysis of Total Harmonic Distortion ( THD ).
- Graphic Phase diagram with 3-Phase system parameters.
- 3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor
- Calculated Unbalanced Current through Neutral Line ( An )
- Capture Transient events (including Dip, Swell and Outage ) with programmable threshold ( % ).
- Programmable CT ratio ( 1 to 600 ) and PT ratio ( 1 to 1000 ).
- ACV input impedance is 10 Mega ohms
- Safety Standard : IEC 1010, CAT III 600V.