Phenix Technologies offers a rugged, portable line of AC high voltage equipment for dielectric testing of aerial lift platforms and trucks. These units provide a complete testing solution in one convenient package. The standard safety features combined with advanced metering make the Phenix line of aerial lift high voltage test systems the premium choice for testing single trucks to maintaining a whole fleet.
Model | BK60 | BK130/36 | BK180 | |
Input |
Voltage/Current | 110-120 V, 10 A 208-240 V, 6 A |
110-120 V, 30 A 208-240 V, 15 A |
110-120 V, 30 A 220-240 V, 15 A |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | |
Output |
Voltage/Current | ≈ 0-60 kV, 10 mA | ≈ 0-36 kV, 180 mA ≈ 0-130 kV, 50 mA |
≈ 0-180 kV, 18 mA |
Duty Cycles |
5 min ON/15 min OFF | 10 mA | 50 mA/180 mA | 18 mA |
1 hr ON/1 hr OFF | 7 mA | 33.3 mA/120 mA | 12 mA | |
Continuous | 5 mA | 25 mA/90 mA | 9 mA | |
Digital Metering |
Metering Accuracy | 0.8% Reading + 0.2% Full Scale | 0.8% Reading + 0.2% Full Scale | 0.8% Reading + 0.2% Full Scale |
Voltmeter Range(s) | 0-60 kV | 0-36/130kV | 0-180kV | |
Currentmeter Range(s) | 0-200 µA/2 mA/ 20 mA | 0-200 µA/2 mA/ 20 mA/200 mA | 0-200 µA/2 mA/ 20 mA |
Safety and Design Features
- Two-piece design
- Circuit breaker protection
- External interlock provision
- High Voltage On/Off pushbuttons with indicator
- Zero Start interlock
- Manual control of output voltage
- Adjustable overload circuit
- Slow and fast-acting transient protection on all meters and relays
- Digital timer with audible alarm
- Digital multi-range metering
- Emergency Off pushbutton with key lockout (excluding model BK60)
- Guard mode for accurate current measurements
- Output overload indicator with reset switch
- All Interconnect control and power cables are included
- Cable storage provision
- Operation/maintenance manual
- BK130/36 model uses inductive reactive compensation to reduce input power