Tektronix understands that engineers rely on an oscilloscope throughout their design cycle, from prototype turn-on to production testing. The DPO7000 Series oscilloscopes’ unique capabilities combined with exceptional signal acquisition performance and analysis accelerate your measurement tasks.
Notice to EU customers
This product is not updated to comply with the RoHS 2 Directive 2011/65/EU and will not be shipped to the EU. Customers may be able to purchase products from inventory that were placed on the EU market prior to July 22, 2017 until supplies are depleted. Tektronix is committed to helping you with your solution needs. Please contact your local sales representative for further assistance or to determine if alternative product(s) are available. Tektronix will continue service to the end of worldwide support life.
Key performance specifications
- 3.5 GHz, 2.5 GHz, 1 GHz, and 500 MHz bandwidth models
- Up to 40 GS/s real-time sample rate on one channel, up to 20 GS/s on two channels, and up to 10 GS/s on three or four channels
- Up to 500 Megapoint record length with MultiView Zoom™
- >250,000 wfms/s maximum waveform capture rate with FastAcq®
- FastFrame™ segmented memory acquisition mode with >310,000 waveforms per second capture rate
- User-selectable bandwidth limit filters for better low-frequency measurement accuracy
DPO7054C | DPO7104C | DPO7254C | DPO7354C | ||
Input Channels | 4 | ||||
Bandwidtd | 500 MHz | 1 GHz | 2.5 GHz | 3.5 GHz | |
Rise Time 10% to 90% (Typical) | 460 ps | 300 ps | 160 ps | 115 ps | |
Rise Time 20% to 80% (Typical) | 310 ps | 200 ps | 100 ps | 95 ps | |
DC Gain Accuracy | ±1% witd offset/position set to 0 | ||||
Bandwidtd Limits | Depending on instrument model: 3.0 GHz, 2.5 GHz, 2 GHz, 1 GHz, 500 MHz, 250 MHz, and 20 MHz | ||||
Effective Number of Bits (Typical, sine wave input at instrument bandwidtd, 50 mV/div, 50 Ω Input Impedance, maximum sample rate, 20k point record lengtd) | 6.8 bits | 6.7 bits | 5.6 bits | 5.6 bits | |
Random Noise (RMS, typical, sample mode, full BW, maximum sample rate, 50 Ω) | |||||
Step Gain | 1 V | 19.4 mV | 19.72 mV | 24.48 mV | 26.28 mV |
500 mV | 10.5 mV | 10.89 mV | 14.91 mV | 16.46 mV | |
200 mV | 4.72 mV | 4.69 mV | 6.70 mV | 7.26 mV | |
100 mV | 2.64 mV | 2.70 mV | 4.11 mV | 4.49 mV | |
50 mV | 1.07 mV | 1.10 mV | 1.53 mV | 1.65mV | |
20 mV | 0.487 mV | 0.484 mV | 0.678 mV | 0.735 mV | |
10 mV | 0.273 mV | 0.279 mV | 0.414 mV | 0.458 mV | |
5 mV | 0.173 mV | 0.191 mV | 0.285 mV | 0.303 mV | |
2 mV | 0.112 mV | 0.121 mV | 0.142 mV | 0.148 mV | |
1 mV | 0.087 mV | 0.090 mV | 0.098 mV | 0.100 mV |
DPO7054C | DPO7104C | DPO7104C witd Option 2SR | DPO7254C/DPO7354C | ||
Maximum Sample Rate (1 ch) | 20 GS/s | 20 GS/s | 40 GS/s | 40 GS/s | |
Maximum Sample Rate (2 ch) | 10 GS/s | 10 GS/s | 20 GS/s | 20 GS/s | |
Maximum Sample Rate (3-4 ch) | 5 GS/s | 5 GS/s | 10 GS/s | 10 GS/s | |
Maximum Equivalent Time Sampling Rate | 4 TS/s | ||||
Maximum Record Lengtd witd Standard Configuration | 125 M (1 ch), 50 M (2 ch), 25 M (3-4 ch) | ||||
Maximum Record Lengtd witd Option 5RL | 250 M (1 ch), 125 M (2 ch), 50 M (3-4 ch) | ||||
Maximum Record Lengtd witd Option 10RL (sample rates ≥2.5 GS/s) | — | — | — | 500 M (1 ch) 250 M (2 ch) 125 M (3-4 ch) | |
Maximum Duration at Highest Real-time Sample Rate (1 ch) | 1-2 ms witd standard record lengtd, up to 10 ms witd optional record lengtd | ||||
Time Base Range | 1.25 ps/div to 8 Ms/div | 1.25 ps/div to 8 Ms/div | 1.25 ps/div to 8.19 Ms/div | 1.25 ps/div to 8.19 Ms/div | |
Time Resolution (in ET/IT mode) | 500 fs | 500 fs | 250 fs | 250 fs |
- Ease of use features
- Pinpoint® Triggering provides the most flexible and highest performance triggering, with over 1400 combinations to address virtually any triggering situation
- Visual Trigger and Search precisely qualifies triggers and finds unique events in complex waveforms
- Advanced Search and Mark to find specific events in the entire waveform
- MyScope® custom control windows and right mouse click menus for exceptional efficiency
- 53 automated measurements, waveform histograms, and FFT analysis for simplified waveform analysis
- TekVPI® Probe Interface supports active, differential, and current probes for automatic scaling and units
- 12.1 in. (307 mm) bright XGA display with touch screen
- Optional serial triggering and analysis
- Automated Serial Triggering, Decode, and Search Options for I2C, SPI, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and USB 2.0
- Automated Serial Analysis Options for MIPI® D-PHY DSI-1 and CSI-2, 8b/10b, Ethernet, and PCI Express
- Clock Recovery from serial data streams
- 64-bit NRZ Serial Pattern Trigger for isolation of pattern-dependent effects up to 1.25 Gb/s
- Optional technology specific analysis
- Software Solutions provide built-in domain expertise for MIPI® D-PHY, Ethernet, Automotive Ethernet, MOST, and USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagrams, Power, DDR Memory Bus Analysis, and Wideband RF
- Limit and Mask Testing provide quick insight into signal characteristics
Comments are closed.